Test Equipment...
Halide Test Equipment
NCS Model LMP-2000 New Model!
The LMP-2000 is a state-of-the-art digital instrument specifically developed for carbon in-place testing per ANSI/ASME N510.
|
 |
Like the earlier generation LMP-10, the LMP-2000 is housed in a field-rugged aluminum case, which contains an on-board carrier gas cylinder. Some of the many updated features include an external cylinder shut-off valve, floppy disk drive, LCD data display, numeric keypad, and a microprocessor controlling all internal functions. Computer data output includes a chromatogram, raw data, upstream and downstream tracer gas concentrations, instrument calibration data, system identification, and final results. The detailed report requires only an authorized signature for completion.
Using on-board instructions, only minimal training is required for plant personnel to perform an in-place leak test on a carbon adsorbed bank. A Quick Start Guide is included that will have you up and running in a matter of minutes.
- SUPERIOR TRACER GAS SENSITIVITY
- DISTINGUISHES TRACER GAS FROM BACKGROUND
- USABLE WITH R-11, R-112, AND PERFLUOROCARBONS (PDCB)
- SINGLE DETECTOR MEASUREMENT CONFIGURATION
- BASED ON A STANDARD ANALYTICAL TECHNIQUE
ONBOARD FEATURES:
- Microprocessor control of data analysis and output
- Data output via RS-232 to PC for data storage and report generation
- Floppy disk data storage
- Direct data analysis and report generation capability
- Chromatogram and report output via printer and/or PC
The LMP-2000 is an easy test instrument to master. The LMP-2000 automatically identifies tracer gas desorption resulting from wet or degraded carbon and calculates the system leak rate from a best fit, non-linear plot to time zero. This feature takes the guess work out of testing when working with difficult systems that exhibit rapid tracer gas desorption.
FLOWRATE ACCESSORY PACKAGE
The optional flowrate accessory package for the LMP-2000 allows the user to perform duct and stack flowrate measurements using the methodology specified in ASTM E2029 "Standard Method for Volumetric and Mass Flow Rate Measurement using Tracer Gas Dilution". In this standard test method, tracer gas is injected into a duct or stack at a known rate and the resulting concentration in the duct measured.
Using the flowrate accessory package, the LMP-2000 will monitor the tracer gas injection rate, automatically sample for tracer gas concentration, and calculate a duct flowrate. In many cases duct or stack flowrate data can be obtained more quickly and more accurately using the LMP-2000 in conjunction with the flowrate accessory than with conventional hot wire or Pitot tube traverse methods.
NCS Model LMP-6
- Portable Self Contained
- Minimum operator training
- Stable refrigerant output
- External compressed gas not required
SPECIFICATIONS:
Maximum metered R-11 output: 52 gm/min
Reservoir capacity: Nominal 1 liter
Delivery pressure: 40-50 PSIG
Power requirements: 120±10%, VAC 50/60 Hz, 3 AMP
Weight: 23lbs.
|
 |
Aerosol Test Equipment
ATI manufactures the smallest, lightest photometers available in portable
self-contained units. Our photometers have been designed with the user in mind
for simplicity of operation and virtually maintenance-free use. Both our digital
and analog units are available in version suitable for nuclear applications.
Optional scanning probe and rugged carrying case are also available.
2h

- size 10.1" x 14.3" x 5.8" (25.7 cm x 36.3 cm x 14.7 cm)
- weight 15.5 lbs. plus 2.5 lbs. for scanning probe and access. = 18.0 lbs
(7.0 kg plus 1.1 kg for scanning probe and access = 8.2kg)
- enclosure Instrument enclosures are rugged, die cast aluminum and have a
swiveling handle that also acts as a support.
- power 100 to 250 volts AC, 50/60 Hz fused power entry module.
Automatically adjusts to all standard voltages used worldwide. Please specify
power cable requirements when ordering unit.
- auto-ranging Provides 6 decodes of display from 0.000.1% to 100.0%,
eliminating the manual range selection switch.
- auto zero Automatically establishes zero when sampling the airflow
through the internal ULPA reference filter or when sampling the downstream
airflow by pressing the 0% button.
- alarm larm feature sounds, if enabled, and causes main & probe displays
to flash when user adjustable set point is exceeded.
- bargraph Solid-state bargraph with high visibility LED's on control panel
and scanning probe.
- amplifier Solid-state linear amplifier.
- photometer accuracy 1% of full scale for the decode in use (ratio metric
operation).
- digital display Shows % Leakage from 0.000.1% to 100.0%
- dynamic range 0.0001 to 125 micrograms per liter. Improved firmware
prevents system errors by blanking the display when sampling above 125
micrograms per liter; display is restored when concentration decreases. "HIGH"
mode enables sampling of concentrations exceeding 200 micrograms per liter.
- light source Stable, solid-state scattering chamber light source allows
operation of lower power, generating less heat, and reduced stray light values.
Life expectancy is 50,000 to 100,000 hours.
- repeatability 0.5% full scale
- scattering chamber Field-tested design provides efficient and reliable
performance. A three-stage "OPTICS" indicator ensures accurate internal
reference response; Green = +/- 5% of original value, Orange = +/- 5-10% of
original value, Red = > +/- 10% of original value.
- vaccuum pump 1 cubic foot (28.3 liter) per minute sample rate, using a
twin-head, carbon vane design, for quiet operation and dependability. Attached,
external HEPA filter captures any expelled particulate. "FLOW" indicator ensures
operation within required parameters.
- output a DB9 connector is provided standard on all units for RS232
output.
2ha

- size 10.1" x 14.3" x 5.8" (25.7 cm x 36.3 cm x 14.7 cm)
- weight 15.5 lbs. plus 2.5 lbs. for scanning probe and accessories = 18.0
lbs (7.0 kg plus 1.1kg for scanning probe and accessories = 8.1 kg)
- enclosure Instrument enclosures are rugged, die cast aluminum and have a
swiveling handle that also acts as a support.
- power 100 to 250 volts AC, 50/60 Hz fused power entry module with spare
fuses. Automatically adjust to virtually all standard voltages used worldwide.
Please specify power supply cable when ordering unit (UL/CS/VDE).
- alarm Audible Alarm in unit sounds when adjustable set point is exceeded.
LED on probe lights up when set point is exceeded.
- amplifier Solid-state linear amplifier.
- photometer accuracy +/- 2% of full scale for the decade in use.
- dynamic range 0.0001 to 125 micrograms per liter.
- light source Improved, longer lasting and more stable solid-state
scattering chamber light source. Photometer operates at lower power generating
less heat and lower stray light values. Life expectancy is 50,000 to 100,000
hours.
- repeatability 1.0% full scale
- scattering chamber Redesigned smaller, lighter and more efficient for
improved performance. Easier to clean and requires less maintenance.
- vacuum pump True 1 cubic foot per minute (cfm) sample rate (28.3 liters
per minute) using a twin head, carbon vane pump for quiet operation and attached
to the outlet of the vacuum pump to entrap any particles from the pump exhaust.
- output A DB9 connector is provided standard on all units for a 0-1 VDC
output.
ATI manufactures portable Laskin nozzle aerosol generators which produce a
submicron
polydispersed aerosol in concentrations from 10 to 100 micrograms per liter at
air flows from 50 to 8,100cfm @ 20 psig. All three Laskin nozzle generators
feature rugged stainles steel construction, large fill ports, individual nozzle
control and a 3" standard sanitary fitting outlet. An optional adapter is
available for introducing the aerosol into positive pressure systems. Whatever
your testing needs, we have a generator that will work for your application.
tda-4b lite

- aerosol output range 50-4,000 cfm
- aerosol concentration 100 ug/1 @*: 405 cfm
- aerosol concentration 10 ug/1 @*: 4,050 cfm
- generator type 1 to 3 laskin nozzles
- compressed air 3 to 9 cfm @ 20 psi
- aerosol type poly-dispersed (Cold)
- size 10" L x 8" W x 9" H (25 cm L x 20 cm W x 23 cm H)
- weight 12 lbs. (5.5 kg)
- electrical (not required)
tda-4b

- aerosol output range 50-8,100 cfm
- aerosol concentration 100 ug/1 @*: 810 cfm
- aerosol concentration 10 ug/1 @*: 8,100 cfm
- generator type 1 to 6 laskin nozzles
- compressed air 3 to 18 cfm @ 20 psi
- aerosol type poly-dispersed (Cold)
- size 10" L x 11" W x 9" H (25 cm L x 28 cm W x 23 cm H)
- weight 16 lbs. (7.3 kg)
- electrical (not required)
tda-6c

- aerosol output range 50-2,000 cfm
- aerosol concentration 100 ug/1 @*: 200 cfm
- aerosol concentration 10 ug/1 @*: 2,000 cfm
- generator type 2 to 6 laskin nozzle jets
- compressed air (not required, unit has built-in compressor)
- aerosol type poly-dispersed (Cold)
- size 21" L x 11" W x 8" H (54 cm L x 28 cm W x 20 cm H)
- weight 55 lbs. (25 kg)
- electrical 120 VAC, 60HZ or 220V, 50HZ
tda-5b

TDA-5B produces a sub micron polydispersed aerosol in concentrations from 10
to 100
micrograms per liter at airflows from 1,500 to 65,000 cfm. The TDA-5B is
recommended for certification applications where the required aerosol volume or
concentration may vary widely from high to low (such as in large cleanroom
plenums or individual filter units, where compressed air is not available, or
portability necessary). An optional adapter is available for directing aerosol
to an introduction point operating at less than ambient atmospheric pressure.
- aerosol output range 1,500-65,000 cfm
- aerosol concentration 100 ug/1 @*: 6,500 cfm
- aerosol concentration 10 ug/1 @*: 65,000 cfm
- generator type heated chamber
- compressed air not required
- compressed gas (inerf)* 20 cfh @ 50 psi
- aerosol type poly-dispersed
- size 14" L x 10" W x 10" H (35 cm L x 25 cm W x 25 cm H)
- weight 20 lbs. (25 kg)
- electrical 110 VAC / 60HZ or 220V / 50HZ
*For high volume output, more uniform particle size, and safety, the liquid
is aerosolized, superheated to vapor then re-condensed by ambient air into a
poly-dispersed aerosol. The propellant must be an inert gas since the liquid
vapor temperature is above the liquid flashpoint.
Test Reagents

- PAO (Emery 3004/PAO-4)
available in 1 and 5 gallon containers, MSDS available upon request CAS # 68649-12-7
- DOP (DEHP)
available in 1 and 5 gallon containers, MSDS available upon request CAS # 117-81-7
- PSL (Poly Styrene Latex Spheres)
available in 1 gallon containers, MSDS available upon request, containers of
pre-mixed, near mono-dispersed solution in the following sizes: 0.13 micron, 0.178 micron, 0.22 micron, 0.33 micron, 0.54 micron
|